Interministerial order of November 29, 2008 - Classification of the energy efficiency of domestic appliances
This regulation applies to:
- Refrigerators, freezers and combined appliances
- Domestic air conditioners
- Domestic lighting
Regarding domestic energy conditioners the classes are determined as follow:
Split and multi-split air conditioners (air-cooled):
- A class: 3,20 < EER
- B class: 3,20 = EER > 3,00
- C class: 3,00 = EER > 2,80
- D class: 2,80 = EER > 2,60
- E class: 2,60 = EER > 2,40
- F class: 2,40 = EER > 2,20
- G class: 2,20 = EER
Packaged air conditioners (air-cooled):
- A class: 3,00 < EER
- B class: 3,00 = EER > 2,80
- C class: 2,80 = EER > 2,60
- D class: 2,60 = EER > 2,40
- E class: 2,40 = EER > 2,20
- F class: 2,20 = EER > 2,00
- G class: 2,00 = EER
Single ducted air conditioners (air-cooled):
- A class: 2,60 < EER
- B class: 2,60 = EER > 2,40
- C class: 2,40 = EER > 2,20
- D class: 2,20 = EER > 2,00
- E class: 2,00 = EER > 1,80
- F class: 1,80 = EER > 1,60
- G class: 1,60 = EER
Split and multi-split air conditioners (water-cooled):
- A class: 3,60 < EER
- B class: 3,60 = EER > 3,30
- C class: 3,30 = EER > 3,10
- D class: 3,10 = EER > 2,80
- E class: 2,80 = EER > 2,50
- F class: 2,50 = EER > 2,20
- G class: 2,20 = EER
Packaged air conditioners (water-cooled):
- A class: 4,40 < EER
- B class: 4,40 = EER > 4,10
- C class: 4,10 = EER > 3,80
- D class: 3,80 = EER > 3,50
- E class: 3,50 = EER > 3,20
- F class: 3,20 = EER > 2,90
- G class: 2,90 = EER
Split and multi-split air conditioners (air-cooled in heating mode):
- A class: 3,60 < COP
- B class: 3,60 = COP > 3,40
- C class: 3,40 = COP > 3,20
- D class: 3,20 = COP > 2,80
- E class: 2,80 = COP > 2,60
- F class: 2,60 = COP > 2,40
- G class: 2,40 = COP
Packaged air conditioners (air-cooled in heating mode):
- A class: 3,40 < COP
- B class: 3,40 = COP > 3,20
- C class: 3,20 = COP > 3,00
- D class: 3,00 = COP > 2,60
- E class: 2,60 = COP > 2,40
- F class: 2,40 = COP > 2,20
- G class: 2,20 = COP
Single ducted air conditioners (air-cooled in heating mode):
- A class: 3,00 < COP
- B class: 3,00 = COP > 2,80
- C class: 2,80 = COP > 2,60
- D class: 2,60 = COP > 2,40
- E class: 2,40 = COP > 2,10
- F class: 2,10 = COP > 1,80
- G class: 1,80 = COP
Split and multi-split air conditioners (water-cooled in heating mode):
- A class: 4,00 < COP
- B class: 4,00 = COP > 3,70
- C class: 3,70 = COP > 3,40
- D class: 3,40 = COP > 3,10
- E class: 3,10 = COP > 2,80
- F class: 2,80 = COP > 2,50
- G class: 2,50 = COP
Packaged air conditioners (water-cooled in heating mode):
- A class: 4,70 < COP
- B class: 4,70 = COP > 4,40
- C class: 4,40 = COP > 4,10
- D class: 4,10 = COP > 3,80
- E class: 3,80 = COP > 3,50
- F class: 3,50 = COP > 3,20
- G class: 3,20 = COP
Want to know more about this policy ? Learn more (French)