Regulation on buildings energy performance (PEB Wallonia) 2012
Governance
Development Authority: Operational Directorate General for Spatial Planning, Housing, Heritage and Energy of the Walloon Public Service
Implementation Authority: la Direction des bâtiments durables du Service public de Wallonie
Prescriptive Compliance path
Energy Requirements:
Insulation
U-Values (W/m2.K)
Windows
Walls
Roof
Door
Floor
All climate zones
1.3
0.32
0.27
2.2
0.35
End-uses considered:
Auxiliary devices, Space cooling, Space heating, Water heating, Ventilation
Resources
Notes
Climate zones
Development Authority: Operational Directorate General for Spatial Planning, Housing, Heritage and Energy of the Walloon Public Service
Implementation Authority: la Direction des bâtiments durables du Service public de Wallonie
Prescriptive Compliance path
Energy Requirements:
Insulation
U-Values (W/m2.K)
Windows
Walls
Roof
Door
Floor
All climate zones
1.3
0.32
0.27
2.2
0.35
End-uses considered:
Auxiliary devices, Space cooling, Space heating, Water heating, Ventilation
Resources
Notes
Climate zones
Want to know more about this policy ? Learn more